Table 7

Simulation model validation against literature data.

Parameter Unit Pure CO2 Pure CO2 Oxyfuel PCC Pure CO2
Source [8] [8] [8] [9] [10]
Inlet pressure bar bar 15 15 15 1.01 4.6
Final pressure bar 151 151 151 90 130
Liquefaction pressure bar N/A 62 N/A N/A 25
Inter-cooling temperature °C 38 38 38 10 35
Compressor stages No. 4 2 4 8 3
Pumping stages No. 0 1 0 0 1
Stage pressure drop bar N/A N/A N/A 0.5 0.1
Equation of state PR PR PR TREND PR
Compressor efficiency % 80 80 80 85 75
Pump and compressor power kWh/tCO2 36.9 32 39.6 92.9 62
Power – this study kWh/tCO2 36.85 32.1 39.1 91.6 61.3
Difference % 0.14 −0.31 1.3 1.4 1.1

PR: Peng-Robinson. [8] uses PR in REFPROP, [10] uses PR in Aspen HYSYS. Oxyfuel: Composition is 96.78% CO2. For simulation in this study REFPROP has been used as back-end in CoolProp. PCC: Post Combustion Capture. The source uses 99.99% pure CO2 but the validation is against 100% pure CO2. The power reported from [10] is total power including refrigeration compressor power in addition to compression and pumping power. Value read from graph.