Table 1

Parameters of PMSG.

Parameter Unit Value
Rated power of wind turbines PN MW 1.5
Rated frequency of permanent magnet machine frN Hz 30
Rated voltage of permanent magnet machine UmN kV 0.72
Rotor flux linkage ψf Wb 3.1
D-axis inductance of stator Lsd mH 1.832
Q-axis inductance of stator Lsq mH 0.916
Inertia time constant of rotorTj s 2
Speed outer ring (kp1ki1) / (5, 10)
Machine side inverter d-axis current inner loop (kp2ki2) / (5, 1000)
Machine side inverter q-axis current inner loop (kp3ki3) / (5, 1000)
Rated voltage of grid side inverter UN kV 0.62
DC capacitor voltage udc kV 1.15
DC capacitor C F 0.09
Filter inductance of grid side inverter Lf mH 0.15
DC voltage outer loop (kp4ki4) / (10, 1000)
D-axis current inner loop of grid side converter (kp5ki5) / (0.1, 50)
Q-axis current inner loop of grid side converter (kp6ki6) / (0.9, 50)
Filter time constant Ts s 0.0011