Table 1
Parameters of the Hybrid DG system.
Parameter | Value |
---|---|
PV array | |
Manufacturer and model | Sharp NU-SC350, 349.965 W |
Open circuit voltage ![]() |
46.9 V |
Short circuit current ![]() |
9.6 A |
Maximum power point voltage ![]() |
38.5 V |
Maximum power point current ![]() |
9.09 A |
Series-connected modules per string | 10 |
Parallel strings | 43 |
PMSG | |
Stator resistance | 0.9585 Ω |
Stator inductance | 0.835 μH |
Torque constant | 4.29 Nm/A |
Inertia | 0.0027 kg.m2 |
Wind turbine | |
Mechanical output power | 150 kW |
Base wind speed | 10 m/s |
Rotor diameter | 24.6 m |
Swept rotor area | 475 m2 |
Battery | |
Nominal voltage | 500 V |
Rated capacity | 1000 Ah |
Grid | 11 kV, 50 Hz |