Table 1

Parameters of the Hybrid DG system.

Parameter Value
PV array
 Manufacturer and model Sharp NU-SC350, 349.965 W
 Open circuit voltage ( V oc ) $ ({V}_{{oc}})$ 46.9 V
 Short circuit current ( I sc ) $ ({I}_{{sc}})$ 9.6 A
 Maximum power point voltage ( V mpp ) $ ({V}_{{mpp}})$ 38.5 V
 Maximum power point current ( I mpp ) $ ({I}_{{mpp}})$ 9.09 A
 Series-connected modules per string 10
 Parallel strings 43
PMSG
 Stator resistance 0.9585 Ω
 Stator inductance 0.835 μH
 Torque constant 4.29 Nm/A
 Inertia 0.0027 kg.m2
Wind turbine
 Mechanical output power 150 kW
 Base wind speed 10 m/s
 Rotor diameter 24.6 m
 Swept rotor area 475 m2
Battery
 Nominal voltage 500 V
 Rated capacity 1000 Ah
Grid 11 kV, 50 Hz