Table 5

Best-fit distribution for subsystem using TBF and TTR data.

Sr. No. Subsystem Best fit distribution with parameters (for TBF) Best fit distribution with parameters (for TTR) MTBF (h) MTTR (h)
1. Balance of the system 2P Weibull: Beta = 1.25; Eta (h) = 113.47 Normal: Mean (h) = 1.64; Std (h) = 1.01 26.65 1.64
2. Inverter 3P Weibull: Beta = 0.730583; Eta (h) = 6.378812; Gamma (h)= 21.7 1P Exp: Mean Time (h) = 5.28 105.68 5.28
3. Protection system Weibull 3P: Beta = 0.8; Eta (h) = 4.64: Gamma (h) = 21.7 Normal: Mean (h) = 1.69; Std (h)=1.03 267.87 1.30
4. String Normal: Mean (h) = 13,624; Std (h) = 12,288 1P Exp: Mean Time (h) = 0.88 13,624.00 0.88
5. Power conditioning unit Weibull 3P: Beta = 0.62; Eta (h) = 170.95; Gamma (h) = 21.94 Normal: Mean (h) = 3.99; Std (h) = 4.13 16,565.00 3.99