Table 5

Best-fit distribution for subsystem using TBF and TTR data.

Sr. No. Subsystem Best fit distribution with parameters (for TBF) Best fit distribution with parameters (for TTR) MTBF (h) MTTR (h)
1. Balance of the system 2P Weibull: Beta = 1.25; Eta (h) = 113.47 Normal: Mean (h) = 1.64; Std (h) = 1.01 26.65 1.64
2. Inverter 3P Weibull: Beta = 0.730583; Eta (h) = 6.378812; Gamma (h)= 21.7 1P Exp: Mean Time (h) = 5.28 105.68 5.28
3. Protection system Weibull 3P: Beta = 0.8; Eta (h) = 4.64: Gamma (h) = 21.7 Normal: Mean (h) = 1.69; Std (h)=1.03 267.87 1.30
4. String Normal: Mean (h) = 13,624; Std (h) = 12,288 1P Exp: Mean Time (h) = 0.88 13,624.00 0.88
5. Power conditioning unit Weibull 3P: Beta = 0.62; Eta (h) = 170.95; Gamma (h) = 21.94 Normal: Mean (h) = 3.99; Std (h) = 4.13 16,565.00 3.99

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.