Main experimental studies on BTMS including LHPs.

Year Author Capillary structure Working fluid Heat load Heat flux (W/cm2) Cooling temperature Evaporator temperature (°C) Thermal resistance (K/W)
2015 Hong et al. [10] Grooves Water 20–80 W 0.06–0.4 25 °C–30 °C 32–58 °C 0.13–0.53
2016 Putra et al. [11] Grooves+1 screen 300 mesh Water 20, 40, 82 W 0.48, 0.96, 1.96 28 °C 36–60 °C 0.45–0.8
Alcohol 37–50 °C 0.30–0.85
Acetone 25–50 °C 0.22–0.4
2018 Ariantara et al. [12] Sintered copper powder nc 20, 30, 40 W nc 28 °C 45–65 °C nc
2021 Bernagozzi et al. [13] Porous wick Water Up to 150 W nc 5–20 °C 32 °C nc
Ethanol
2021 Bernagozzi et al. [14] Porous wick Novec 649 Up to 140 W (dissipated from the battery) nc 20 °C Up to 60 °C with ethanol nc
Ethanol Up to 40 W (received by the LHP) Up to 47 °C with Novec 649
2022 Hashimoto et al. [16] Grooves and porous wick R134a Up to 80 W nc −20 °C–20 °C Up to 70 °C 0.1–1.0