Metric | Parameter | PID | ANN | FLC | ANFIS (Proposed) | References |
---|---|---|---|---|---|---|
Voltage stability | Voltage deviation (∆V) | ±5 V | ±3 V | ±4 V | ±2 V | [45, 46] |
Voltage ripple (%) | 5.5% | 3.2% | 4.0% | 1.8% | [47, 48] | |
Charging efficiency | Charging time (full cycle) | 1.2 h | 1.0 h | 1.1 h | 0.8 h | [49, 50] |
SoC management | SoC drop during peak load (%) | 70% | 60% | 65% | 55% | [51–53] |
SoC recovery time (s) | 3.0 s | 1.8 s | 2.5 s | 1.2 s | [54, 55] | |
Power quality | Power ripple (%) | 5% | 3.5% | 4% | 1.5 | [56, 57] |
System response | Overshoot (%) | 12% | 6% | 8% | 4% | [58, 59] |
Settling time (s) | 2.5 s | 1.3 s | 2.0 s | 0.7 s | [60] | |
Energy utilization | Energy utilization efficiency (%) | 85% | 90% | 88% | 95% | [61, 62] |