Open Access

Table 2

System design parameters.

Units Parameters Values
Solar Rated power 3 kW
PV module voltage 240 V
Switching-frequency 8 kHz
Wind Rated power 6.5 kW
Wind output voltage 400 V
Switching frequency 8 kHz
BESS Rated capacity 200 Ah
Switching frequency 8 kHz
Filter Inductor (Lf) 22.26 mH
Inductor (Lc) 0.79 mH
Filter (Cf) 50 μF
Damping resistor (Rd) 5.3 Ω
Load-1 Power 2 kW
Load-2 Power 3.5 kW
Load-3 Power 2 kW
Load-4 Power 3.5 kW
Grid Voltage 400 V
Power 5 kW

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.