Table 8

Comparison of proposed green building with other buildings in winter [3].

S. No. Description Time Conventional building [3] Average of green building 1, 2, 3 & 4 [3] Proposed green building in this paper %age Improved in this paper as compared with average of Green Building 1, 2, 3 & 4 [3]
1 Air contaminants (ppm) Morning 4.23 0.64 0.4 37%
Afternoon 4.48 1.19 1.19 0%
Evening 4.67 1.28 1 22%
2 Humidity (%) Morning 58 51.80 47 9%
Afternoon 57 51.25 45 12%
Evening 54.6 52.63 46 13%
3 Lighting (Lux) Morning 226 853.33 890 4%
Afternoon 245 907.23 985.2 9%
Evening 237 859.25 912 6%
4 Temperature (°C) Morning 12.26 19.53 19.4 1%
Afternoon 12.28 21.68 21.1 3%
Evening 11.3 19.98 19.7 1%
5 Noise(dB) Morning 43 45.62 42.3 7%
Afternoon 41 45.33 44.5 2%
Evening 44.66 45.77 45 2%