Table 4

Summary of the existing case studies of hybrid renewable energy systems.

Case study Location Components Control Strategy Findings Reference
Hybrid renewable energy system for rural electrification Bangladesh Solar panels, wind turbines, diesel generators ANFIS Improved energy efficiency (85%) and stable voltage levels; reduced reliance on diesel. [33, 34]
Hybrid solar-wind-battery system Greece 50 kW solar PV, 30 kW wind turbine, 100 kWh battery Fuzzy Logic Controller (FLC) Mild voltage fluctuations; overall system efficiency of around 78%; adapted well to weather conditions. [35, 36]
Solar-wind hybrid system with ANN control India Solar PV, wind energy system, battery storage Artificial Neural Network (ANN) Optimized battery charging/discharging; achieved 80% efficiency; maintained stable supply. [35, 37]
Integrated hybrid energy system for urban development China Solar, wind, microgrid system Combination of PID and ANFIS Improved system stability and energy efficiency by 10% compared to PID alone; better load management. [38]