Comparative analysis of fault detection and location methods.
| Parameters | Various fault detection and location methods |
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PS | [13] | [19] | [23] | [64] | [22] | [4] | [18] | [21] | [5] | [7] | [15] | [36] | [37] | |
| FD parameters | C–C | FC–C | L–C | L–C and LV | L–C | C–C | C–C | L–C | L–I | L–C | C–C | C–C | L–C | C–C |
| No. of sources | 5 | 4 | 4 | 6 | 4 | 2 | 4 | 2 | 2 | 6 | 1 | 7 | 4 | 6 |
| Rf | 10 | 0.1 | 0.6 | 200 | 2 | 10 | 25 | x | x | 50 | 10 | 2 | 100 | 2 |
| Sensing (v, i) | i | i | i | v,i | I | i | i, v | i | i,v | i,v | v,i | v,i | v,i | i |
| FD time (ms) | 2.3 | 1.98 | x | <2 | 2 | 1.5 | 1.25 | x | 10 | 2 | 1.25 | 100 | 19 | 1 |
| FL (TL, LS) | LS | TL | TL | TL | TL | LS | TL | TL | LS | TL | TL | T-L | T-L | T-L |
| Fault classification | Yes | No | No | Yes | No | Yes | Yes | No | No | Yes | No | No | No | No |
| Errors in D (%) | 2.59 | x | x | 5 | 8.32 | x | 7.1 | x | 2 | 3.59 | 8.7 | 6.42 | 1.6 | 9.75 |
| DCMG with the EV station | Yes | Yes | Yes | No | No | Yes | Yes | No | No | Yes | No | No | No | No |
| Cable required for FL calculation | Yes | Yes | Yes | Yes | No | Yes | Yes | No | Yes | No | Yes | Yes | Yes | Yes |
PS = proposed scheme, L–C = line current, L–V = line voltage, FC–C = filter capacitor current, C–C = capacitor current, x = not given, FD = fault detection, FL = fault location, TL = transmission line, LS = load side, D = fault distance.