Table 2

Comparative analysis of fault detection and location methods.

Parameters Various fault detection and location methods
PS [13] [19] [23] [64] [22] [4] [18] [21] [5] [7] [15] [36] [37]
FD parameters C–C FC–C L–C L–C and LV L–C C–C C–C L–C L–I L–C C–C C–C L–C C–C
No. of sources 5 4 4 6 4 2 4 2 2 6 1 7 4 6
Rf 10 0.1 0.6 200 2 10 25 x x 50 10 2 100 2
Sensing (v, i) i i i v,i I i i, v i i,v i,v v,i v,i v,i i
FD time (ms) 2.3 1.98 x <2 2 1.5 1.25 x 10 2 1.25 100 19 1
FL (TL, LS) LS TL TL TL TL LS TL TL LS TL TL T-L T-L T-L
Fault classification Yes No No Yes No Yes Yes No No Yes No No No No
Errors in D (%) 2.59 x x 5 8.32 x 7.1 x 2 3.59 8.7 6.42 1.6 9.75
DCMG with the EV station Yes Yes Yes No No Yes Yes No No Yes No No No No
Cable required for FL calculation Yes Yes Yes Yes No Yes Yes No Yes No Yes Yes Yes Yes

PS = proposed scheme, L–C = line current, L–V = line voltage, FC–C = filter capacitor current, C–C = capacitor current, x = not given, FD = fault detection, FL = fault location, TL = transmission line, LS = load side, D = fault distance.