Open Access
Table 4
System operation parameters.
Parameter | Description | Value | Unit |
---|---|---|---|
Mv | Vapor Molar Mass | 18 × 10−3 | kg mol−1 |
Ma,atm | Air Molar Mass | 29 × 10−3 | kg mol−1 |
![]() |
Oxygen Molar Mass | 32 × 10−3 | kg mol−1 |
![]() |
Nitrogen Molar Mass | 28 × 10−3 | kg mol−1 |
kca,in | Cathode Inlet Orifice Constant | 0.36 × 10−5 | kg s−1 pa−1 |
![]() |
Oxygen Mole Fraction | 0.21 | – |
Vca | Cathode Volume | 0.01 | m3 |
Vsm | Supply Manifold Volume | 0.02 | m3 |
Patm | Atmospheric Pressure | 101,325 | Pa |
Psat | Saturation Pressure | 465,327.41 | Pa |
Tatm | Atmospheric Temperature | 298.15 | K |
Tst | Stack Temperature | 353.15 | K |
R | Universal Gas Constant | 8.31 | J mol−1 K−1 |
CD | Cathode Outlet Throttle Discharge Coefficient | 0.012 | – |
Cp | Constant Pressure Specific Heat of Air | 1004 | J mol−1 K−1 |
F | Faraday Number | 96,485 | C mol−1 |
n | Number of Cells | 381 | – |
AT | Cathode Outlet Throttle Area | 0.002 | m2 |
γ | Ratio of Specific Heat of Air | 1.40 | – |
ϕatm | Average Ambient Air Relative Humidity | 0.50 | – |