Open Access
Table 1
Main experimental studies on BTMS including LHPs.
Year | Author | Capillary structure | Working fluid | Heat load | Heat flux (W/cm2) | Cooling temperature | Evaporator temperature (°C) | Thermal resistance (K/W) |
---|---|---|---|---|---|---|---|---|
2015 | Hong et al. [10] | Grooves | Water | 20–80 W | 0.06–0.4 | 25 °C–30 °C | 32–58 °C | 0.13–0.53 |
2016 | Putra et al. [11] | Grooves+1 screen 300 mesh | Water | 20, 40, 82 W | 0.48, 0.96, 1.96 | 28 °C | 36–60 °C | 0.45–0.8 |
Alcohol | 37–50 °C | 0.30–0.85 | ||||||
Acetone | 25–50 °C | 0.22–0.4 | ||||||
2018 | Ariantara et al. [12] | Sintered copper powder | nc | 20, 30, 40 W | nc | 28 °C | 45–65 °C | nc |
2021 | Bernagozzi et al. [13] | Porous wick | Water | Up to 150 W | nc | 5–20 °C | 32 °C | nc |
Ethanol | ||||||||
2021 | Bernagozzi et al. [14] | Porous wick | Novec 649 | Up to 140 W (dissipated from the battery) | nc | 20 °C | Up to 60 °C with ethanol | nc |
Ethanol | Up to 40 W (received by the LHP) | Up to 47 °C with Novec 649 | ||||||
2022 | Hashimoto et al. [16] | Grooves and porous wick | R134a | Up to 80 W | nc | −20 °C–20 °C | Up to 70 °C | 0.1–1.0 |