Open Access
Table 9
Comparison of proposed green building with other buildings in summer [3].
S. No. | Description | Time | Conventional building [3] | Average of green building 1, 2, 3 & 4 [3] | Proposed green building this paper | %age Improved in this paper as compared with average of green building 1, 2, 3 & 4 [3] |
---|---|---|---|---|---|---|
1 | Air contaminants morning (ppm) | Morning | 6.64 | 1.30 | 1.21 | 7% |
Afternoon | 6.68 | 1.59 | 1.42 | 11% | ||
Evening | 6.38 | 1.30 | 0.9 | 31% | ||
2 | Humidity (%) | Morning | 74 | 55.50 | 49 | 12% |
Afternoon | 79 | 57.25 | 51 | 11% | ||
Evening | 78 | 55.58 | 50 | 10% | ||
3 | Lighting (Lux) | Morning | 346 | 1078.32 | 1295 | 20% |
Afternoon | 368 | 1258.75 | 1535 | 22% | ||
Evening | 366 | 1068.25 | 1350 | 26% | ||
4 | Temperature (°C) | Morning | 42.66 | 26.08 | 21 | 19% |
Afternoon | 48.66 | 28.29 | 24.2 | 14% | ||
Evening | 45 | 26.00 | 23.1 | 11% | ||
5 | Noise (dB) | Morning | 64.33 | 51.09 | 40 | 22% |
Afternoon | 68 | 53.73 | 45.3 | 16% | ||
Evening | 64.45 | 50.90 | 48.1 | 5% |