Table 2

PAR as a function of pressure and CO2 concentration.

Partial pressure of CO2 (bar) Dissolved CO2 concentrationa (mol/kg) Average peak area ratiob () Standard deviation
3.010 0.1315 0.06957 0.00120
2.500 0.1092 0.05905 0.00116
2.015 0.0880 0.04874 0.00139
1.550 0.0677 0.03872 0.00134
1.043 0.0456 0.02527 0.00121
0.721 0.0315 0.01740 0.00102
0.334 0.0146 0.00794 0.00094
0.115 0.0048 0.00218 0.00126
a

Calculated from pressure and temperature using Henry’s law constant.

b

The average peak area ratio is calculated from all experimental data points at equilibrium (Fig. 5). The calibration curve is fitted from all experimental data points, linking the variation of the PAR to the concentration of the dissolved CO2 (Fig. 6a) or the partial pressure of the CO2 (Fig. 6b). The uncertainty (1σ) of the predicted CO2 dissolved concentration and the partial pressure are ±0.003 mol·kg−1 and ±0.05 bar, respectively.