Table 1

Components and parameters of the DC microgrid.

Symbol Quantity Value
DC–DC converter
L1 to L4 Inductors 7.14 mH
C1 to C9 Capacitors 473.4693 μF
Resr1Resr9 ESR of a capacitor 0.036 Ω
D1 to D6 Diodes
Q1 to Q 6 IGBTs
RL1 to RL6 Resistance of the loads 25 Ω
Rf1, Rf2 Range of fault resistance 0.5–10 Ω
DC-link operating voltage 90 V
PV and wind of the DC–DC converter 2.32 kW
Grid VSC 2.43 kW
Bat1 converter 253 W
Bat2 converter 249 W
Switching frequency 5 kHz
Battery parameters
Battery voltage/Capacity 48 V/35 Ah
PV Parameters
Vmp (PV), Imp (PV) Voltage at MPP, Current at MPP 67 V, 19.22 A
Voc (PV), Isc (PV) Voltage at OC, Current at SC 90 V, 25.76 A
Wind Parameters
Vmp(wind), Imp(wind) Voltage at MPP, Current at MPP 67.20 V, 19.5 A
Voc(wind), Isc(wind) Voltage at OC, Current at SC 89.61 V, 26 A
Cable parameters
RC1–6, RC12 Cable (line) resistances (R) 12.1 Ω/km [length of the cable = 90 m]