Table 1
System simulation parameters.
Parameters | Value |
---|---|
Grid-side three-phase voltage/kV | 110 |
Grid-side Frequency/Hz | 50 |
V-v Traction Transformer ratio | 110/27.5 |
Step-down transformer ratio | 27.5/1 |
Output inductance of AC side of converter/mH | 0.01 |
DC side capacitance/mF | 20 |
DC side reference voltage/kV | 1650 |