Table 4

Calculated transient parameters of Tie line power, Ptie, for the studied test system Scenario 1.

Algorithms ΔPtie12
Tr (s) Ts (s) Mp (%) Tp (s)
CHOA [Studied] 0.0126 8.5834 0.0079 0.9179
COA [Studied] 0.0132 7.9469 0.0039 0.6769
AEFA [Studied] 0.0139 14.7236 0.0036 0.7174
ARO [Studied] 5.1536 11.1434 0.0044 0.8666
SO [Studied] 0.0139 8.2913 0.0034 0.6547
AGTA [Proposed] 0.0115 7.5111 0.0027 0.5613

The bold font represents that the proposed algorithm provide better results as compared to the other algorithms.