Table 1

Handheld multimeter measurements and status.

Visual inspection group Diode number Forward diode test [V] Reverse diode test [V] Forward resistivity test [Ohm] Reverse resistivity test [Ohm] Defect status
A 1 0.137 OL 333 OL I
A 2 0.135 OL 381 OL I
A 3 0.134 OL 335 OL I
A 4 0.134 OL 370 OL I
A 5 0.122 OL 310 OL I
A 6 0.138 OL 370 OL I
A 7 0.138 OL 384 OL I
A 8 0.138 OL 360 OL I
A 9 0.131 OL 305 OL I
A 10 0.167 OL 450 OL I
A 11 0.133 OL 350 OL I
A 12 0.112 OL 260 OL I
A 13 0.137 OL 360 OL I
A 14 0.135 OL 340 OL I
B 15 0 0 0.5 0.5 x
B 16 0 0 0.5 0.4 x
B 17 0 0 1.7 1.7 x
B 18 0 0 1.2 1.2 x
B 19 0 0 1.6 1.6 x
B 20 0 0 3.1 3.2 x
B 21 0 0 0.8 0.8 x
B 22 0 0 0.8 0.8 x
B 23 1.64 2.67 OL OL o
B 24 OL OL OL OL o
B 25 OL OL OL OL o
B 26 2.006 2.42 OL OL o
B 27 0 0 1.8 1.8 x
B 28 0 0 1.4 1.4 x
C 29 2.58 2.58 OL OL o
C 30 2.83 2.98 OL OL o
C 31 0 0 1.2 1.2 x
C 32 0.75 1.1 OL 1800 o
C 33 OL OL OL OL o
C 34 OL OL OL OL o
C 35 1.25 1.27 2200 2200 x
C 36 OL OL 3,800,000 4,900,000 o