Table 1

System parameters [1].

Parameter Values
Residential building 2 kWh
Single-phase AC grid Single-phase, 230 V, 50 Hz
PV system 1.5 kW, 89.7 V, 16.4 A
Wind energy system 1.0 kW, three-phase, 103.8 V
Battery stack 96 V, 150 A h, 50% SOC
Low-voltage DC load 0.3 kW at 48 V
Medium voltage DC load 1 kW at 380 V
AC loads 0.4 kW (0.9 pf), 0.42 kW (0.9 pf)
DC bus capacitor 2200 μF
DC and AC filters 11 mH, 105 μF (DC), 5 mH, 10 μF (AC)
IBAT_Lim ±20 A

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.