Open Access

Table 2

PV modules specifications.

Parameters at STC CS3U-390MS CS3W-390P FS-6390
Company Canadian solar Canadian solar First solar
Rated power (W) 390 390 390
Voltage at max. power (V) 40.4 40.8 173.9
Current at max. power (A) 9.66 9.56 2.24
Open circuit voltage (V) 48.2 48.6 214.8
Short circuit current (A) 10.17 10.17 2.49
Fill factor 0.796 0.789 0.728
Efficiency (%) 19.2 18.9 15.8
NOCT (°C) 45 45 45
Cell type Mono Poly Thin-Film
Surface area (m2) 1.984 1.984 2.475